VersaNet2
Ever
since its launch in 1990 VersaNet has led the field in low power radio
telemetry systems. VersaNet2 maintains the versatility and flexibility
of the original system whilst introducing up to the minute features for
increased security and ease of use.
VersaNet2 saves the cost and disruption associated with the installation
and maintenance of conventional data transmission methods such as cable,
fibre optic or public telecom network.
VersaNet2 accepts signals from all types of standard industrial transducers
(analogue, digital (on/off) or pulse count.). It then sends these signals
, usually by uhf radio to one or more remote receiving points where they
maybe output in their original form or to a computer based SCADA system
or both.
What makes VersaNet2 unique is the highly intelligent communications
controller in every unit and its truly modular structure.
Secure Data Transmission
VersaNet2 - The smart choice.
The intelligent VersaNet2 controller ensures efficient and
secure transmission you can rely on. Following are some of
the features that make VersaNet2 the smart choice.
- Listen before transmit - saves wasted transmissions on
shared bands.
- Radio Protocol employing message acknowledgements
and automatic re-tries provides transmission security.
- Multiple error checks - ensure data integrity at
every stage.
VersaNet2 will find the way.
In the event of a unit in a network failing VersaNet2 will automatically
take an alternative route through the system so maximising system security.
Passing on the message.
Powerful repeater functions mean VersaNet2 can reach difficult locations
not possible with other systems. Every VersaNet2 node is a repeater -
even a low power node. There is no limit to the number of repeater steps.*1
One Product - Many Applications
VersaNet2's unique modular structure makes it suitable for any system
from the simplest point-to-point link to large systems with many hundreds
of I/O. Whatever the system size or type the same interchangeable building
blocks will be used meaning simplified parts holding - just one of the
ways we make life easy for our customers.
- Minimum Node configuration - 1 dig and 1 pulse I/O
- Maximum Node capacity - 128 each of digital, analogue and
pulse hardwire inputs and outputs.*1
- See specification for details of I/O card types
The right connections.
VersaNet2's serial port allows connections to PLC's, Scada systems etc.
through standard industrial protocols. They can also be used to connect
to alternative data transmission media.
New Connectivity for VersaNet2
Powerful new VersaNet2 features allow users total flexibility in system
planning and operation. As well as stand alone uhf radio VersaNet2 can
now communicate through GSM or conventional land line modems. This facility
may simply be used to reach locations not available to the uhf radio because
of range or terrain.. Alternatively it may be used in conjunction with
VersaNet2's powerful primary and secondary routing features to
provide an automatic backup communication for total system security.
For maximum efficiency the user may determine the exact sets of conditions
including combinations of elapsed time, digital status, analogue values
and changes that cause a GSM connection to be made.
Keeping in touch with VersaNet2
VersaNet2's new SMS feature will automatically send text messages to
key personnel when prompted by up to 64 predefined sets of conditions
anywhere in your VersaNet2 system. The content of the message is dynamic
allowing the inclusion of I/O variables and engineering units to give
an exact clear message.
Example
|
|
 |
VersaNet2 can hold
up to 32 phone
numbers so you can
ensure that the
right message gets
to the right person. |
 |
VersaNet2 will even
send text messages
regarding its own
status. |
Keeping you informed
For simple fault finding and commissioning VersaNet2 provides a powerful
package of facilities ranging from simple LED indications of system status
to the free issue windows based "Node Manager" which will give
access to system configuration details, monitors I/O status and facilitates
system tests.
No special knowledge, No special equipment
The design of VersaNet2 has been focused on ease of installation and
set-up. No specialist knowledge or equipment is needed for a successful
implementation as free issue, Node Manager software helps you every step
of the way. Node Manager tells you the channel occupancy, received signal
strength, monitors the status of alarms, inputs and outputs, and turns
on remote units for signal tests. You can even adjust the transmitter
power to compensate for signal loss/gain associated with different cables
and antennae.
No power? - No problem!
Like it's predecessor, VersaNet2 is engineered to transmit Pulse, Analogue
or Status signals from remote locations powered by battery or compact
solar panel. New Power Save features allow you to control a digital output
and even place a repeater node at an un-powered location.
The world approves of RDT!
VersaNet2 conforms to Council Directive 1999/5/EC (R&TTE). In the
UK it may be used without a license under regulations formerly known as
MPT1329. In most countries VersaNet2 can be operated with minimal regulatory
restrictions. RDT have gained specific approvals for VersaNet2 in Europe,
Scandinavia, America, Africa and other countries, reducing formalities
for the user. Our policy of continual development means new approvals
for our product range are regularly being sought. We are happy to provide
answers to detailed requirements.
Unrivalled support and backup
RDT designs every element of VersaNet2 in-house. Only RDT can bring you
this level of expertise as well as providing detailed, efficient and rapid
reponse to all customer requests. Clear, well-presented and accurate manuals
covering every aspect of system implementation support all RDT products.
We also supply and advise on related items such as solar/wind power supplies,
overseas approvals, antennae requirements, etc.
Quality at every stage
RDT are an accredited ISO9002 Company. As well as our products we take
a pride in the quality of every aspect of our business including customer
service and short reliable delivery promises.
System features
Node to node Communications media.
- integral uhf radio - GSM - PSTN System capacity - up to 250 nodes*1
Unlimited repeater functions
System Features
Product features
Modular architecture.
Single board solutions for simple systems
Indication of transmit. carrier detect & decode, alarm &
run.
Node manager features
Fully widows compatible
Selects:- network name, node number, operating frequency, transmitter
power, number of retries, report rate, alarm delay and low power
operation.
Defines:- mapping of inputs to outputs, conditions for transmission,
primary and secondary routes through the network
Diagnostic Functions:- displays I/O status, received signal strength,
forced transmit mode, channel occupancy indication. Saves node configurations
and prints record sheets.
GSM and SMS features
Up to 128 dynamic messages
Up to 32 destinations.
Up to 64 multi level transmit triggers
|
Radio Specification
Frequency Range |
800KHz band in the range 406 - 470MHz |
Channel Spacing |
10, 12.5, 20 or 25KHz |
Modulation |
FFSK |
Transmitter
|
Output power |
500mW (adjustable) |
Adjacent Chan |
-37dBm |
Freq. Tolerance |
+/- 1KHz |
FM deviation |
+/- 2KHz (12.5KHz chan.) |
Intermod attenuation |
>40dB |
Spurious emissions |
<-36dBm 0-1GHz
<-30dBm 1-4GHz |
Receiver |
Sensitivity |
(12.5KHz) -110dBm for
15dB SINAD |
Co-channel rejection |
>-12dB |
Adj. Channel selectivity |
>60dB |
Spurious response rejection |
>70dB |
Intermod response rejection |
>70dB |
Blocking >84dB for any signal from tuned frequency. |
>50KHz |
Spurious emissions |
<-57dBm 0-1GHz
<-47dBm 1-4GHz |
Meets R&TTE directive |
Contact RDT for details of other approvals. |
|
I/O |
Controller Card |
1xdig in |
1xdig out |
1xpulse in |
1xpulse out |
|
/A option |
1x0-20mA in |
1x0-20mA out |
Comms fail alarm output. |
|
I/O cards |
- up to 16 of each of the following per node:- |
8 x Digital/ pulse inputs |
8 x Digital outputs |
8 x Analogue inputs |
4 x Analogue outputs |
8 x pulse inputs |
8 x Alarm outputs |
Mixed type I/O cards:- |
4 analogue in plus 4 digital in with PSU. |
| 4 analogue in plus 4 digital in (low power) |
2 analogue out plus 4 digital out |
| |
Analogue resolution - 12 bit. |
| |
Pulse input can be sent to anologue ouput to
give indication of flow rate. |
| |
Serial I/O |
RS232 MODBUS ASCII or RTU |
MODBUS address space 2048 each of Ain, Aout, |
| Dig in and Dig out per node. |
|
Physical
Size
Standard Housing 190mmx280mmx130mm.
Larger housings available depending on I/O.
Units may be supplied without housing for mounting in control
panels.
Weight
3.5 Kilo typical depending on I/O.
Enclosure Material
Grey UV resistant Polycarbonate.
Temperature
-20C to +60C
Available Power Supplies
12Vdc - 24Vdc - 110Vac - 240Vac
Specify at time of order.
Options
Battery Back-up
Solar Power |
Click
here for the full data sheet
Accessories
RDT can supply a wide range of accessories including antennas &
power amplifiers.
N.B. *1 - Overall system capacity is limited by the capacity of the radio
channel. Although individual figures given are correct the amount of I/O,
number of nodes, required update rate and radio path losses may combine
to limit items marked thus *1`
E & OE |